VCD 07160-01 Rev. -

Less than 400W

from 400W to 499W

from 500W AND UP

Other

VTA 07160-01
Rechargeable Battery Pack Ð Rack Mountable  
FEATURES
- High energy density Rechargeable Sealed Lead-Acid Batteries. Valve regulated with superior performance and safe operation in any position.
- Easy access battery replacement panel with captive screws.
- Battery pack connection: using basic building block of 12 volt batteries connected in parallel and series combination to form the 24V battery pack.
- Battery capacity rating Ò C Ó 10 Amps for 30 min
- Built-in D-SUB 5W5 connector to connect to an external 15A/50VDC two poles Circuit Breaker ÒCBÓ for battery over-current protection and battery disconnect.
- 2 toggle switches used to enable a momentary battery load testing.
- Reverse polarity protection (only when coupled with RIC500).
- Convection cooled unit, no fans required.
- Standard 19Ó Rack Mountable with mounting interface designed to accept externally sourced Jonathanª slides P/N130QD-16.
- Battery checker circuit with LED Panel Mount Indicators labeled ÒGOODÓ (green) and ÒBADÓ (yellow).
- Deep-discharge protection.
- Battle short override of the Deep Discharge Protection function.
- 3/4 inch hose flange to vent battery gases.
- Wide operating temperature range
- Shelf life is 6 months at 20¼C ambient from full charge.
1) Charger Voltage Rating 27.6 Volts Max
2) Maximum Charge Current 3.5 Amps
3) Nominal Charge time at 2 Amps charging current 7 Hours 15Min (No Efficiency Loss)
4) Hi-Pot I/O to Chassis 10 MegaOhms at 500 Volts DC
Output:
1) Output Voltage Range 22.0 to 27.5 Volts
2) Maximum Output Current 10 Amps at 22 Volts
3) Nominal Capacity 20 hours rate (725 mA to 21.0 V): 14.5 Amp-Hours.
4) Min Hold-up Time 30 minutes at 10 Amps (batteries fully charged at floating voltage 27.6Volts) Battery Pack Protection and Control:
1) Deep-Discharge Cut-off Voltage 20 to 21Volts
2) Reverse Polarity Protection Yes, when used with RIC 500
3) Circuit Breaker Trip current 15 Amps
4) Battle Short Control Controllable via J2 (pin 1-2) or J3 (pin 1-2), with maintained action contact. Maximum open circuit contact voltage 30 volts and closed circuit contact voltage of 0.6 volts at 10 mA Max.
Battery Test
1) Nominal Load and Test Duration 6 ohms. Load testing at C/2 (5 Amps for 15 sec)
2) Test Activation switches via S1 and S2 switched to momentary ON.
3) Test Result Panel indicators (LED) Good=Green, Bad=Yellow.
4) Maximum Test Duration 60 seconds.
5) Operating Range 10 to 40 Volts
Physical Specifications:
1) Weight < 50 lbs or 22.7 kilograms (Kg)
2) Case Aluminum Alloy 5052-H32, 0.090 inch thick
3) Finish (Front Panel) Anodic Coating, MIL-A-8625, Type III
4) Finish (Housing) Chemical Film, MIL-C-5541, Class 3
5) Cooling Natural convection
6) Mounting 19Ó Rack with drawer slide interface
7) Mounting Holes 4 front panel accepting 1/4 in screws
8) Battery Gas Exhaust 0.75 in diameter flange
9) Connectors I/O Power connectors (J2/J3): D-SUB 7W2P CB Connector (J4): D-SUB 5W5 S
10) Electrical Bonding and Grounding Resistance between chassis and chassis ground stud less than 2.5 mOhms at 15Amps.
Environmental Specifications:
1) Shock 50GÕs - half sine wave, 11msec, 3 axes. -------------------------- 2) Operating Temperature -20¼C to +50¼C
3) Storage Temperature -20¼C to +70¼C -------------------------- 4) Altitude Maximum 15,000 ft
5) Humidity Operating: 20% to 80% non-condensing Storage: 0% to 80% non-condensing
Reliability:
1) Reliability Prediction (MIL-HDBK-217F) With batteries 28,000 hrs at 50¼C ( N S ) Without batteries 84,000 hrs at 50¼C ( NS )