VCD 05010-01 Rev. 01

 
VTA 05010-01 
3 Phase, 400Hz, 809W Power Supply. 
FEATURES
- Up to 694 Watts VME Output Power
- Two separate Fan supplies, STIR and COOL. (115W combined)
- Maximum power output 809W.
- High Input/Output Isolation.
- Low Output Ripple.
- Short Circuit Protection.
- Thermal Protection.
- Input and Output Status Signals
- VME Bus Signals.
This Power Supply, used in VME applications, features a low profile package of 14.3Ó L x 8.1Ó W x 3.25Ó H or 2.15 Watt/in3. It has excellent load
regulation, input filtering, and low output ripple as well as current limiting and internal thermal shutdown protection. 
Input Specifications:
(1) Steady State Voltage 108 to 118 VAC, MIL-STD-704E
(2) Surge Voltage Over voltage: MIL-STD-704A, Cat A, Fig 2 Curve 1 Under voltage: MIL-STD-704A, Cat A, Fig 2 Curve 6
(3) Frequency 380Hz to 420Hz, MIL-STD-704A
(4) Frequency Transients ±50Hz, MIL-STD-704A, Fig. 5, Curves 2 and 3.
(5) Isolation Resistance 1 M½ Phases or Neut to chassis @ 500 Vdc
(6) Inrush Current ² 20A Peak, per phase
(7) Power Factor (>50% rated load) 0.85 
Power Supply Control:
Control is provided for disabling the VME outputs when an external temperature sensor contact opens above a user defined threshold. The FAN supplies (STIR +24V and COOL +24V) are ON whenever AC input is applied to the Power Supply. The outputs are enabled as follows:
(8) i) TEMPSENSE_3 Closed O/Ps ON: VME O/Ps, STIR +24V, COOL +24V
ii) TEMPSENSE_3 Open O/Ps ON: STIR +24V, COOL +24V 
Output Specifications:
(9) Nominal Rated DC (10) Ripple Max. Current
Voltage Current Regulation & Noise Power Limiting
+5 VDC 100A ±0.2 Vdc <50mV p-p 500W 156 A max
+3.3 VDC 50.0A ±0.2 Vdc <30mV p-p 165W 112 A max
+12 VDC 1.4A ±0.5 Vdc <100mV p-p 16.8W 2.7 A max
Ð12 VDC 1.0A ±0.5 Vdc <100mV p-p 12.0W 2.7 A max
STIR +24V 2.4A ±0.96 Vdc <500mV p-p 57.6W 8.15A max (1)
COOL +24V 2.4A ±0.96 Vdc <500mV p-p 57.6W 8.15A max (1)
(11) Over-voltage Protection < 125% of Rated O/P Voltage, any VME channel.
(12) Over-current Protection Each O/P is current limit/ short circuit protected, Limits as above. VME O/Ps have UV detection to shutdown O/Ps in event of overcurrent.
Note 1: COOL & STIR +24V combined I limit is 8.15A.
(13) Efficiency > 70% at full load.
(14) Remote Sense 5V and 3.3V O/P, 150mV on supply & return.
(15) Load regulation remain in tolerance for load changes 65% to 70% Any other load change, return and remain in tolerance within 0.5ms
(16) Stabilization time <1s.
(17) Hold up time 50ms at rated output for VME O/Ps.
(18) ACFAIL* Status TTL open collector Asserted atVin 104Vac, unassert 108Vac, to ANSI VITA 1-1994
(19) AC Present LED Open collector cathode connection, active when ACFAIL* is unasserted I limited to 20mA max
(20) DC OK* Status TTL open collector asserted when all O/Ps are within tolerance
(21) DC Present LED Open collector cathode connection, active when DC OK* is unasserted, I limited to 20mA max.
(22) FAN PWR OK* Status TTL open collector asserted when STIR +24 or COOL+24 on.
(23) Heater Power LED None.
(24) VME RESET Signals To ANSI VITA 1-1994
i) Power down reset: Asserted 50s prior to 5V < 4.850V 25mV
ii) Power up reset: Asserted before 5V >2V, remain asserted for 0.2s t 0.4s after ACFAIL* unasserted and 5V > 4.850V 25mV
(25) Isolation Input to output 500V, output to chassis 50V
(26) Bonding Connector shells to heat sink 2.5mohms.
(27) Over temperature signal TTL open collector asserted at rising baseplate of 95¡C ±5¡C, with 5¡C to 15¡C hysteresis. (TBC)
(28) Thermal shutdown Partial or complete shutdown at base plate temperature 100¡C (TBC). 
Environmental Specifications:
(29) Temperature i) Operating: -25C to +65C, 11.5lbs/min cooling, (equiv 150cfm at standard temperature, 25¡C, and pressure sea level) at the rated load.
ii) Storage: -40C to +71C
(30) Humidity Operating: up to 95% non-condensing Non operating: up to 100% condensing
(31) Altitude Operating: Sea level to 15000 ft, rapid decompression, 8,000 to 35,000 ft Non operating: Up to over pressure of 170kPa (-15000 ft).
(32) Fungus To Guideline 4 of MIL-STD-454
(33) Shock Functional: 3 x 6g, 11msec terminal peak sawtooth,. 3 axes. Crash: 2 x 30g, 11msec terminal peak sawtooth,. 3 axes.
(34) Bench Handling Shock To MIL-STD-810E, Method 516.4, Procedure VI.
(35) Vibration To MIL-STD-810E, Method 514.4 Cat 4 (Propeller Aircraft and Turbine Engines) Procedure I: Figure 514.4-7: F1 = 68Hz; L1=0.3g2/Hz. Free of
resonance modes in all axes at 17± 2Hz; 68 ± 8Hz and 136 ± 16Hz.
(36) EMC MIL-STD-461E: Fig CE101-4 Curve #1 plus 16dB, Fig CE102-1= basic curve +6dB (115V), +12dB 10 to 50kHz, Fig CS101-1 Curve #1
(37) Storage No servicing after 24 months at 15¡C t 30¡C, 15% RH 50%.
(38) Safety Guideline 1 of MIL-HDBK-454 and MIL-STD-1472D, para. 5.13.
(39) Reliability Prediction To MIL-HDBK-217F N2, >20,000 hrs at 30C, Airborne Inhabited Cargo